  • This Acti9 iC60N is a low voltage miniature circuit breaker (MCB). It is a 1P circuit breaker with 1 protected pole, 10A rated current and C tripping curve. The rated short circuit breaking capacity goes up to 50kA at 220VAC to 240VAC conforming to EN/IEC 60947-2 standard and 6000A at 230VAC conforming to EN/IEC 60898-1 standard. It complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. This miniature circuit breaker protects circuits against short circuit and overload current. Its unique VisiTrip indicator reduces intervention time by showing the faulty circuit. Its VisiSafe green strip guarantees the physical opening of the contacts to allow downstream maintenance. Its fast closing mechanism independent of manual operation improves its service life. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ui rated insulation voltage is 500VAC. Its limitation class 3 (according to EN/IEC60898-1) improves downstream circuit protection cost. The product can be clipped on a DIN rail. Its width is 2 pitches of 9mm. Pollution degree is 3. Overvoltage category is IV. The product colour is white (RAL9003). The dimensions are (W) 18mm x (H) 91mm x (D) 78.5mm. The weight is 0.125kg. According to IEC 60529 standard, the degree of protection is IP20 and IP40 in enclosure. The operating temperature is -35°C to 70°C. The storage temperature is -40°C to 85°C. 

    Įrenginio taikymas
    Distribution
    Range
    Acti9
    Product name
    Acti9 iC60
    Produkto arba komponento tipas
    Miniature circuit-breaker
    Device short name
    IC60N
    Poles description
    1P
    Number of protected poles
    1
    [In] rated current
    10 A
    Tinklo tipas
    AC
    DC
    Trip unit technology
    Šiluminis-magnetinis
    Curve code
    C
    Breaking capacity
    6000 A Icn 230 V AC 50/60 Hz EN/IEC 60898-1
    10 kA Icu 60...72 V NUOLATINĖ SROVĖ EN/IEC 60947-2
    15 kA Icu 12...60 V NUOLATINĖ SROVĖ EN/IEC 60947-2
    10 kA Icu 220...240 V AC 50/60 Hz EN/IEC 60947-2
    36 kA Icu 12...60 V AC 50/60 Hz EN/IEC 60947-2
    20 kA Icu 100...133 V AC 50/60 Hz EN/IEC 60947-2
    Utilisation category
    Category A EN 60898-1
    Category A IEC 60898-1
    Suitability for isolation
    Yes EN 60898-1
    Yes EN 60947-2
    Yes IEC 60898-1
    Yes IEC 60947-2
    Standartai
    EN 60898-1
    IEC 60898-1
    IEC 60947-2
    EN 60947-2 