Maitinimo šaltinis SIMATIC PM 1507 24V, 8A

  • Kraunamos nuotraukos
    Kodas: 6EP1333-4BA00
    Kaina 180  be PVM
    (217 80  su PVM)
    Likutis: 2 vnt.
    Į krepšelį 
    Gamintojas
    Siemens
  • Regulated power supply for SIMATIC S7-1500 input: 120/230 V AC, output: 24 V DC/8 A 

    Input
    Input 1-phase AC
    ● Note Automatic range selection
    supply voltage
    ● 1 at AC rated value 120 V
    ● 2 at AC rated value 230 V
    input voltage
    ● 1 at AC 85 ... 132 V
    ● 2 at AC 170 ... 264 V
    Wide-range input No
    Overvoltage resistance 2.3 × Vin rated, 1.3 ms
    Mains buffering at Vin = 93/187 V
    Mains buffering at Iout rated, min. 20 ms; at Vin = 93/187 V
    Rated line frequency 1 50 Hz
    Rated line frequency 2 60 Hz
    Rated line range 45 ... 65 Hz
    input current
    ● at rated input voltage 120 V 3.7 A
    ● at rated input voltage 230 V 1.7 A
    Switch-on current limiting (+25 °C), max. 62 A
    duration of inrush current limiting at 25 °C
    ● maximum 3 ms
    I²t, max. 12 A²·s
    Built-in incoming fuse T 6.3 A/250 V (not accessible)
    Protection in the mains power input (IEC 898) Recommended miniature circuit breaker: 16 A characteristic B or 10 A
    characteristic C 

    Output Controlled, isolated DC voltage
    Rated voltage Vout DC 24 V
    ● output voltage at output 1 at DC rated value 24 V
    Total tolerance, static ± 1 %
    Static mains compensation, approx. 0.1 %
    Static load balancing, approx. 0.1 %
    Residual ripple peak-peak, max. 50 mV
    Spikes peak-peak, max. (bandwidth: 20 MHz) 150 mV
    product function output voltage adjustable No
    Status display LED green for 24 V OK; LED red for error; LED yellow for stand-by
    On/off behavior No overshoot of Vout (soft start)
    Startup delay, max. 1.5 s
    6EP13334BA00
    Page 1/3 11/21/2021 Subject to change without notice
    © Copyright Siemens
    Voltage rise, typ. 10 ms
    Rated current value Iout rated 8 A
    Current range 0 ... 8 A
    supplied active power typical 192 W
    short-term overload current
    ● on short-circuiting during the start-up typical 35 A
    ● at short-circuit during operation typical 35 A
    duration of overloading capability for excess current
    ● on short-circuiting during the start-up 70 ms
    ● at short-circuit during operation 70 ms
    Parallel switching for enhanced performance Yes
    Numbers of parallel switchable units for enhanced
    performance 2 

  • Prenumeruok ir laimėk

    Informacija